GN-PT5M3B-R
In stock
Regular price
¥29,535 JPY
Couldn't load pickup availability
Common specification (GN-series)
Switch structure | Dry contact |
---|---|
Movement differential | 0 |
Compatible vacuum | 10-5Pa |
Allowable baking temperature | 120 ℃ |
Contact material | A(NO): PEEK B(NC): SUS HRC45 |
Case material | SUS304 |
Cable | PTFE core-wire cable 0.5m(x2), AWG30 |
Operating temperature range | 0℃ - 120℃ |
Temperature drift | 0 (because of no amplifier) |
---|---|
Oscillation | 10 - 55Hz Total amplitude 1.5 for X, Y, Z each direction |
Impact | 300m/s2 for X, Y, Z each direction |
Contact rating | DC5V - DC24V Steady current: 10mA or less (Rush current: 20mA or less) When using the switch with LED, limit the current below 10mA |
Standard accessory | Two fixing nuts for threaded type |
Notes on repeatability | At operating speed 50 - 200mm/min (operating speed slower than 10mm/min is NOT recommended) |
Questions & Answers (GN-series)
-
How should the switch be contacted with detected objects?
Make contact with detected objects at right angle (within deflection angle ±3°)
If there is a possibility to press the plunger to the stroke end, install a stopper separately to prevent the malfunction. -
How can I wire Metrol switches when replacing cuttently using proximity sensors?
For wiring, please refer to the following.
-
Are CE-Mark Machine Directives / Low Voltage Directives applicable to Metrol products?
Our products are applicable neither to CE-Mark Machine Directives nor to Low Voltage Directives.
-
Are Metrol products RoHS compliant?
Our products comply with RoHS Directive and use lead-free solder.